Please print these instructions before you follow them.
--WARNING!-- Do not allow different versions on various computers to accessing the same data. When you run different versions or different iterations of [any] version on various machines that are all pointed to the same database, you will encounter strange errors with chances of unsolvable data corruption.
Verify the version you are currently running on all machines!
You can find your full, multi-digit version number inside the software. Just click Help > About.
There are also two ways to view the version from [outside] the software.
1. Open your Control Panel and then go to Programs & Features to view it on the list. If it shows Gradience Professional, it will also give the version number similar to one of the illustrations below.
If you don't see the words Gradience Professional disregard it and go to step 2 below.
2. Go to C:\Program Files (x86)\Gradience and open the Common folder. Then scroll down to and right-click on GCore.exe and click on Properties > Details to view the full, multi-digit version number.
The latest version is currently Version 12.
Installation Steps:
Select the type of installation below that best describes your particular need.
--IMPORTANT!-- You will be downloading the entire suite. You will [not] download a particular individual software title. It is only during the installation process that you select the title or titles to be installed.
The First Client Workstation:
At the server, go to C:\ProgramData\Gradience. When you get there, copy the Hrware.ini file and then paste it into a neutral location. Then open the file in that neutral location and change just [one] thing.
You will see [HRWARE] at the top. Now, the second line is the path to the database. Leave this alone. Don't concern yourself with the drive letter that is indicated. Look down to the 4th line where you will see SERVER=Localhost. Change the word Localhost to the name or the IP address of the server or the computer where the database resides. Save the change.
Next, go to the NEW client workstation and navigate to C:\ProgramData and create a Gradience folder and then paste the altered ini file into that folder. [Then] click the link below for the version you need to instsall. You will [not] need to restart the computer when finished.
Download the installer to our latest version here.
During installation the software will automatically point correctly because the installer will see the pre-existing ini file, which is already pointed to the data.
The Second or Additional Client Workstation:
First go to an existing client workstation and go to C:\ProgramData\Gradience. When you get there, copy the Hrware.ini file and then paste it into a neutral location.
Next, go to the NEW client workstation and navigate to C:\ProgramData and create a Gradience folder and then paste the altered ini file into that folder. [Then] click the link below for the version you need to instsall. You will [not] need to restart the computer when finished.
During installation ther software will automatically point correctly because the installer will see the pre-existing ini file, which is already pointed to the data.
If the new client fails to connect to the database visit this ARTICLE